An extension module for VERSA and INTEGRA control panel outputs making it possible to extend a system with 8 additional outputs. Depending on the module variant, this may include "open collector" type outputs, relay outputs or a combination of both these types. The CA-64 OPS module is equipped with a back-up power supply (capacity 2.2 A) ensuring additional power to supply alarm system elements.
- system expansion with 8 outputs
- switching mode power supply
discontinued
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.
Documentation
user manual
updated: 2010-11-24
105 KB
Technical Data
Max. relay switched voltage
24 V
Max. relay switched current
2 A
Board dimensions
142 x 102 mm
Operating temperature range
-10…+55 °C
Max. current consumption
138 mA
Battery failure voltage threshold (±10%)
11 V
Battery cut-off voltage (±10%)
9,5 V
Battery charging current (switch-over)
350 / 700 mA
Supply voltage (±10%)
18 V AC, 50-60 Hz